EPM1602 Gas Analyzer

EPM1602 - Gas Analyzer For Petrol/LPG/CNG Vehicles

Features :-

WaterSense

WaterSense helps detect any water content from the sampling system into the instrument and turns off the pump and stops suction thus prolonging the life of the instrument.

6Gases

Instrument is easily upgradable to measure concentration of 6 gases (NOx, and SOx in addition to CO, HC, CO2 and O2).

AutoZero

The accuracy of the NDIR sensor depends upon temperature factors. Any change in the temperature results in change in the measured values. AutoZero ensures to zero measured values for every 20 minutes by default or for every 2°C change in the temperature.

eLeakCheck

Automatically performs leak-check before any measurement thus aiding user to identify leak if any. It also helps ensure accuracy of measurement.

AutoControls

Helps to switch on/off pump, solenoid valve etc automatically after the respective functions are performed thus increasing the life of the instrument.

SDiagnosis

Checks various functional parameters like HC-residue, warm-up, leak, low flow etc. Assists in detection of faults/failures like O2 sensor failure, NDIR sensor communication failure etc.

PowerSaver

Switches off the display after 5 mins of inactivity thus reducing power consumption.

USB

Equipped with an USB (as well as RS232) interface for easy communication. USB serves as a backup interface when RS232 interface fails. Moreover, present computers are not equipped with RS232 port.

MultiTechRPM

Equipped with RPM sensors capable to measure RPM using Piezo/Battery/Acoustic/Vibration principles thus ensuring zero downtime.

WLRemote

Wireless remote based on bluetooth technology averts use of cables (optional).

WLRPMSensor

An optional wireless RPM sensor for smooth functioning.

WLPrinter

Wireless dot-matrix printer for user-friendly operations (optional).

Technical Specifications

Measured Parameters

Parameters Measurement Methodology Range Resolution Accuracy
CO NDIR 0-15% 0.001% ±5%
HC NDIR 0-20000ppm 1ppm ±5%
CO2 NDIR 0-20% 0.01% ±5%
O2 Electrochemical 0-25% 0.01% ±5%
NOx* Electrochemical 0-5000ppm 1ppm ±5%
SOx* Electrochemical 0-5000ppm 1ppm ±5%
RPM* Battery/Magnetic 400-10000 10 ±2%
OT* RTD 0-150°C 1°C 3°C
Lambda Calculated 0.2-2.0% 0.001% -
AFR Calculated 0-30% 0.01% -

Optional

Other Specifications

Operating Temperature 0-50°C
Measuring Gas Intake 1ltr/min
Response Time <5s (for sampling probe length of 3m)
Warmup Time (≥25°C) <3minutes
Display Type Backlit LCD
Keyboard Membrane keypad (3x4)
Zero/Gas Span Calibration Automatic
Span Calibration Digital
Power Supply 12VDC ±1.2V / 230VAC ±20%
Power Consumption 25W
Leak Test Electronic
Dimension 300 x 265 x 120mm
Weight 5 kg